                                                          Product Details:

                                                          • Voltage 12-30 Volt (v)
                                                          • Color Gray and Green
                                                          • Product Type Loop Powered Clinometer
                                                          • Power DC Volt (v)
                                                          • Operating Temperature -25 to +60 Celsius (oC)
                                                          • Click to View more
                                                          X

                                                          AccuStar - 4 to 20mA Loop Powered Clinometer Price And Quantity

                                                          • INR
                                                          • 1 Piece

                                                          AccuStar - 4 to 20mA Loop Powered Clinometer Product Specifications

                                                          • DC Volt (v)
                                                          • 12-30 Volt (v)
                                                          • Loop Powered Clinometer
                                                          • Gray and Green
                                                          • -25 to +60 Celsius (oC)

                                                          AccuStar - 4 to 20mA Loop Powered Clinometer Trade Information

                                                          • Cash in Advance (CID) Cash Advance (CA)
                                                          • 100 Piece Per Week
                                                          • 3 Days
                                                          • Yes
                                                          • Sample costs shipping and taxes has to be paid by the buyer
                                                          • All India

                                                          Product Description

                                                          The AccuStar IP-66 is a 4 to 20mA loop powered clinometer specifically designed for industrial and outdoor applications. Rated to IP-66, the rugged die-cast, powder coated aluminum housing provides protection in the most hostile environments.

                                                          The heart of the system is our patented, capacitance-based tilt sensor with no moving parts. When rotated about its sensitive axis, this unique sensor provides an exceedingly linear variation in capacitance, which is then electronically converted into 4 to 20mA and VDC analog outputs proportional to the angular position. The AccuStar IP-66 may be operated as either a 2-wire loop powered angle transmitter, or a 4-wire analog output tilt sensor. Mounting features integrated into the die cast housing, make installation onto any vertical surface easy.

                                                          Also see our other models, AccuStar Electronic Clinometer (4 standard input/output configurations), AngleStar Protractor System (AccuStar with digital readout) and AngleStar DP-45 (handheld digital protractor).

                                                          Features :

                                                          Ranges from +3o +45o

                                                          Rugged die-cast aluminum housing

                                                          Dust and water tight to IP-66

                                                          Current or voltage output

                                                          3m (10 ft.) long jacketed cable

                                                          Application :

                                                          Crane safety systems

                                                          Machine tool angle positioning

                                                          Barge leveling and load distribution

                                                          Medical vehicle leveling / mobile CT & MRI

                                                          Mining equipment

                                                          Solar array tracking systems

                                                          ELECTRICAL

                                                          Linear range

                                                          +3o to +45o

                                                          Input voltage (unregulated)

                                                          +12 to +30VDC (+18VDC min. required for 4 to 20mA operation)

                                                          Output*

                                                          4 to 20mA or +0.5 to +4.5VDC (see note)

                                                          Zero (level) output

                                                          12mA or +2.5VDC

                                                          Max loop resistance

                                                          500 at +24VDC

                                                          Linearity

                                                          Null to 10

                                                          +0.1o

                                                          10 to 45

                                                          +1%

                                                          Null repeatability

                                                          0.05o

                                                          Cross axis error

                                                          <1% up to 45o

                                                          Frequency response

                                                          0.5Hz @ -3db

                                                          ENVIRONMENTAL/MECHANICAL

                                                          Operating temperature range

                                                          -25o to +60 oC

                                                          Temp. coefficient of null

                                                          0.05o / oC

                                                          Temp. coefficient of scale factor

                                                          0.1% / oC

                                                          Cable

                                                          Shielded cable with FEP jacket, four conductors, stranded 22 AWG, 3m (10 foot) long min..