                                                          The Universal Industrial Transmitter Product Specifications

                                                          • The Universal Transmitter
                                                          • Black and Grey
                                                          • ABS
                                                          • 15-40 Volt (v)
                                                          • 540 Grams (g)

                                                          The Universal Industrial Transmitter Trade Information

                                                          • Cash Advance (CA) Cash in Advance (CID)
                                                          • 100 Piece Per Week
                                                          • 3 Days
                                                          • Yes
                                                          • Sample costs shipping and taxes has to be paid by the buyer
                                                          • All India

                                                          Product Description

                                                          Problem-free, accurate humidity measurement results from the most stable sensor in the industry combined with our unique HygroClip digital probe technology, designed to practically eliminate any maintenance downtime. When it is time for a scheduled calibration hot swap in seconds with a calibrated probe without loss of measurement accuracy. HygroFlex8 transmitters provide superb precision and state-of-the-art functionality, taking humidity and temperature measurement to a whole new level of performance and reliability (0.8 %rh and < 0.1oC accuracy).

                                                          Innovation In Humidity And Temperature Measurement

                                                          • Highest accuracy at 0.8 %rh and 0.1oC
                                                          • Outstanding long-term stability and chemical resistance
                                                          • Widest Temperature measuring range at -100200 oC
                                                          • Two Interchangeable HygroClip digital or analog probe inputs
                                                          • 10,000 point data logging with time stamp and battery back-up
                                                          • Up to 4 programmable Analog Outputs available
                                                          • Digital Output Options
                                                          • Multiple Alarm Relays
                                                          • Audible and Visual Alarms
                                                          • Galvanically Isolated power supply

                                                          AirChip3000 Digital Technology - The latest generation of ROTRONIC probes and instruments use the AirChip 3000 technology with features such as:

                                                          • Compensates humidity and temperature over 30,000 reference points
                                                          • Dew/frost point calculation
                                                          • Sensor auto-diagnostics and automatic correction
                                                          • Active alarming and information
                                                          • User congurable xed output signals
                                                          • Conforms to FDA21 CFR Part 11 and GAMP4 ( audit trail)

                                                          Optional display :

                                                          • The clear, backlit graphic display is easy to read and the simple menu navigation provides fast access to all the information available
                                                          • Trend indication of values
                                                          • Display resolution to 2 decimal places
                                                          • Calculates and Displays Delta Value between the two probes
                                                          • Three programmable display formats

                                                          Flexible choice of probes :

                                                          • The HygroFlex 8 can be tted with TWO interchangeable
                                                          • HygroClip2 probes
                                                          • Compatible with all HygroClip2 probe types
                                                          • Connection of two analog probes
                                                          • Changing of HygroClip2 probes requires no further adjustment
                                                          • Use of probe simulators allows easy process validation

                                                          Output signals :

                                                          • Four freely selectable and scalable analog outputs
                                                          • Freely selectable output type through HW4 software: 0/420 mA; 01/5/10 VDC
                                                          • Optional digital outputs allow integration on a network via Ethernet or RS-485
                                                          • Combined digital and analogue output signals, allow controlling and steering a device with one transmitter

                                                          Data logging function :

                                                          • Logs up to 10,000 value pairs, relative humidity and temperature provided by a single HygroClip2 probe
                                                          • Logs up to 10,000 data values provided by a single 1-channel analog probe
                                                          • Both probe inputs can be logged at the same time
                                                          • Each record is date and time stamped (real-time clock)

                                                          Relay output :

                                                          • Up to 4 relays
                                                          • Each relay can be programmed individually
                                                          • Each relay can be set to control any measured or calculated parameter

                                                          Alarm function :

                                                          • Visible and audible alarm can be programmed when the HF8 detects the following:
                                                          • Out-of-limits value (dened with the HW4) for each probe input
                                                          • Communication loss with the probe
                                                          • Impaired rh sensor or major sensor failure

                                                          Applications :

                                                          The HygroFlex8-series is ideal for all applications where exact measurement of humidity and temperature is of decisive importance, for example the food and pharmaceutical industries, printing and paper industries, meteorology, agricultural sector, archaeology and climatology. There is hardly a eld today in which these parameters may be ignored. It is ultimately the measuring task at hand that denes the combination of transmitter and probe that best covers your needs

                                                          Probes For Hygroflex Transmitters. :

                                                          Whether you need a more sophisticated industrial probe to measure in a high temperature range or a standard Hygroclip2 probe to measure ambient conditions, we can provide you with the ideal HygroClip2 probe to suit your requirements. All HygroClip2 probes can be individually calibrated and adjusted to increase measurement precision where you need it the most. This capability is exactly what makes every probe in the product range a high-end solution for your application.

                                                          Industrial Probes in general

                                                          Probes for process applications. (xed installation)

                                                          • Operating range: 0100 %rh, -100200 oC (-148392 oF)
                                                          • Pressure: HC2-IE Series: 0400 bar (05,800 PSI)
                                                          • Probe diameter: 15 mm; 25/15 mm, NPT 1/2" or G 1/2" thread

                                                          HC2-IC Series

                                                          • Humidity measuring range: 0100 %rh
                                                          • Temperature limits at sensor: -100200 oC
                                                          • Barrel: PPS
                                                          • Barrel diameter: 15 or 25/15mm
                                                          • Barrel length: 100/250/400/550/700 mm
                                                          • Probe cable length.: 2 m or 5 m

                                                          HC2-IM Series

                                                          • Humidity measuring range: 0100 %rh
                                                          • Temperature limits at sensor: -100200 oC
                                                          • Barrel: Stainless steel
                                                          • Barrel diameter: 15 or 25/15 mm
                                                          • Barrel length: 120/280/430/580 mm
                                                          • Probe cable length.: 2 m or 5 m

                                                          HC2-IE Series

                                                          • Humidity measuring range: 0100 %rh
                                                          • Temperature limits at sensor: -100200 oC
                                                          • Barrel: Stainless steel NPT 1/2" or
                                                          • G 1/2" thread for maximum 400 bar
                                                          • Probe cable length.: 2 m or 5 m
                                                          • Standard Probe
                                                          • Humidity measuring range: 0100 %rh
                                                          • Temperature limits -50100 oC (-58212 oF)
                                                          • Diameter: 15 mm (0.6"), length: 85 mm (3.3")
                                                          • Housing and lter cap: polycarbonate, black

                                                          Technical Specification :

                                                          Device type

                                                          Humidity temperature transmitter with analog output signals relay outputs
                                                          Optional digital interface: Ethernet, RS-485

                                                          Circuit type

                                                          3-wire

                                                          Number of probe inputs

                                                          2 (digital or analog)

                                                          Digital probe

                                                          HygroClip 2 probe

                                                          Analog probe (12-bit AD converter)

                                                          Supply voltage to probe: 5 VDC Maximum probe signal range: 0 to 3.3 VC Congurable measuring range and measurement unit

                                                          Probe type

                                                          All HC2 probes (digital)

                                                          Accuracy at 23 +5 oC

                                                          +0.8 %rh / 0.1 C (typically value), Depends on the probe

                                                          Measurement range

                                                          -100200 oC / 0100 %rh, probe dependent

                                                          Psychrometric calculations

                                                          Dew point (Dp) above and below freezing
                                                          Frost point (Fp) below freezing and dew point above freezing
                                                          Wet bulb temperature (Tw) , Enthalpy (H)
                                                          Vapor concentration (Dv) , Specic humidity (Q)
                                                          Mixing ratio by weight (R), Vapor concentration at saturation (Dvs)
                                                          Vapor partial pressure (E), Vapor saturation pressure (Ew)

                                                          Start-up time

                                                          1.9 s (typical)

                                                          Data refresh rate

                                                          1 s (typical)

                                                          Supply voltage HF83x

                                                          1540 VDC or 1228 VAC, 50-60 Hz

                                                          Supply voltage HF84x

                                                          9-36 VDC, with galvanic isolation

                                                          Supply voltage HF86x

                                                          85265 VAC, 5 Watt, 50-60 Hz with galvanic isolation

                                                          Analogue output 1, 2, 3 and 4

                                                          Analogue output signals, scalable by user
                                                          020 mA 4 20 mA 0 1 V 0 5 V 0 10 V

                                                          Interface options

                                                          RS-485 and analogue output Ethernet (wired)
                                                          RS-485 and analogue output Ethernet with PoE

                                                          Relay 1, 2, 3 and 4

                                                          Can be made to correspond to any parameter and probe

                                                          Parameter, Operation

                                                          User congurable with the ROTRONIC HW4 software

                                                          Relay type

                                                          SPDT (single pole double throw)
                                                          Maximum switching voltage: 250VAC
                                                          Maximum switching current: 6A (resistive load)

                                                          Optional display

                                                          LC, 1 or 2 decimals resolution backlight, trend and alarm indication

                                                          Housing material / Weight

                                                          ABS / 540 g (1 lb 3 oz) - depends on model

                                                          Housing protection grade

                                                          IP 65 (except models with USB or Ethernet interface)

                                                          Storage and transit

                                                          -50+70 oC / -20...+70 oC (models with display)
                                                          0100 %rh, non condensing

                                                          Operating limits at electronics

                                                          -40 +85 oC / -10.60 oC (models with display)
                                                          0100 %rh, non condensing

                                                          Temperature limits at probe

                                                          Depends on probe model

                                                          Maximum humidity at sensor

                                                          100 %rh up to 80 oC (176 oF)
                                                          75 %rh at 100 oC (212 oF)
                                                          45 %rh at 125 oC (260 oF
                                                          15 %rh at 150 oC (302 oF)

                                                          CE / EMC immunity

                                                          EMC Directive 2004/108/EG:
                                                          EN 61000-6-1: 2001, EN 61000-6-2: 2005
                                                          EN 61000-6-3: 2005, EN 61000-6-4: 2001 + A1

                                                          Solder type

                                                          Lead free (RoHS directive)

                                                          Fire protection class

                                                          Corresponds to UL94-HB

                                                          FDA / GAMP directives

                                                          Compatible