Back to top
08045478718
Send SMS    Call Me Free Send Inquiry
                        Carbon Dioxide & Temperature Transmitter for Wall Mounting

                        Carbon Dioxide & Temperature Transmitter for Wall Mounting

                        6000.00 - 30000.00 INR

                        Product Details:

                        • Voltage 24 Volt (v)
                        • Color White
                        • Material ABS
                        • Power DC/AC Volt (v)
                        • Product Type Temperature Transmitter
                        • Type Electronic
                        • Temperature Range 0 to +50 Celsius (oC)
                        • Click to View more
                        X

                        Carbon Dioxide & Temperature Transmitter for Wall Mounting Price And Quantity

                        • 6000.00 - 30000.00 INR
                        • 1 Piece

                        Carbon Dioxide & Temperature Transmitter for Wall Mounting Product Specifications

                        • DC/AC Volt (v)
                        • White
                        • 24 Volt (v)
                        • ABS
                        • Electronic
                        • Temperature Transmitter
                        • 0 to +50 Celsius (oC)

                        Carbon Dioxide & Temperature Transmitter for Wall Mounting Trade Information

                        • Cash Advance (CA) Cash in Advance (CID)
                        • 100 Piece Per Week
                        • 3 Days
                        • Yes
                        • Sample costs shipping and taxes has to be paid by the buyer
                        • All India

                        Product Description

                        A SENSETM is an all - digital low-cost transmitter for installation in the climate zone. It measures both CO2 concentration and temperature in the ambient air. The data is transmitted to a BMS system or controller. aSENSETM is a key component for climate control of buildings and other processes. It is also a cost-efficient gas alarm sensor for spaces where carbon dioxide gas is a potential danger.

                        Features :

                        • State-of-the-art Non-Dispersive Infrared (NDIR) technology to measure CO2
                        • Maintenance free in normal applications
                        • Cost optimized for connection to DDC:s
                        • Contributes to lower energy costs when it is applied in a Demand Control Ventilation (DCV) strategy
                        • Available in different carbon dioxide measurement ranges and different housings
                        • Internal automatic self diagnostics
                        • 2 analogue outputs as standard (V/mA). Relay output as option
                        • Cost-efficient RS485 communication as option
                        • Internal 2-channel logger as option

                        APPLICATIONS

                        A SENSETM is designed to control ventilation by transmitting the measured carbon dioxide and temperature value to the system's Master or DDC. The transmitter is flexible and suits many different ventilation strategies. According to most building regulations, the fresh air flow should, in rooms where people stay more than occasionally, be at least 7 litres/sec and person. If the room occupants are adults with a light work-load and the outdoor CO2 concentration is 350 ppm, this airflow answers directly to an in-door CO2 concentration of 1040 ppm. According to National Boards of Occupational Safety and Health, the CO2 concentration can therefore be used as an indicator of the Indoor Air Quality (IAQ). A CO2 concentration below 1000 ppm should then always be the aim.

                        Specification :

                        General Performance


                        Compliance with

                        EMC directive 89/336/EEC, RoHS directive 2002/95/EG

                        Operating Temperature Range

                        0 to +50oC

                        Storage Temperature Range

                        - 40 to +70oC (standard model) (models -D: -20 to + 70oC)

                        Operating Humidity Range

                        0 to 95% RH (non-condensing)

                        Warm-up Time

                        < 1 min(@ full specs 10 minutes)

                        Sensor Life Expectancy

                        > 15 years

                        Maintenance Interval

                        No maintenance required

                        Self Diagnostics

                        Complete function check of the sensor

                        Display

                        4 Digits, 7 segments LCD with ppm / oC / % indicator (models -D)

                        Electrical/Mechanical


                        Power Input

                        24 VAC/VDC+20%, 50-60 Hz (half-wave rectifier input)

                        Power Consumption

                        < 3 Watts average

                        Wiring Connections

                        Screw terminals, max 1,5 mm2 wires/ European and US standard J-boxes

                        Outputs


                        Analogue3


                        Protection

                        PTC fuse (auto reset) on signal return M, short-circuit safe

                        Linear outputs OUT1 & OUT2

                        0/2-10 VDC ROUT < 100 OHM, Rload > 5k OHM (0/1-5 VDC optional) 0/4-20 mA Rload < 500 OHM

                        Default ranges

                        0 - 2000 ppm CO2, 0 - 50oC

                        D/A Resolution

                        10 bits, 10 mV / 0.016 mA

                        D/A Conversion Accuracy.

                        Voltage mode: + 2% of reading + 50 mV
                        Current loop : + 2% of reading + 0.3 mA

                        ON/OFF


                        Relay (OUT3)


                        UART Serial com port

                        (accessory -R) isolated N.O., 1mA/5V up to 1A/50VAC/24VDC.



                        Protocol.

                        SenseAir protocol (see comprot 0700xx rev 3_04.pdf ) Modbus as option4

                        PC-interface.

                        RS232 UART cable with sliding contact and driver (model A232 Cable)

                        PC User Interface Program

                        UIP4 (or higher)5

                        RS485 network com

                        (accessory -485) RS485 terminal slide-on port, network capabilities up to 30 units

                        LonWorksTM network com.

                        (accessory -LON) LonWorks add-on Option Modbus RTU

                        CO2 Measurement


                        Operating Principle

                        Non-dispersive infrared (NDIR) with Automatic Baseline Correction (ABC)6

                        Response Time (T1/e)

                        2 mindiffusion time

                        Accuracy7

                        + 1% of measurement range + 5 % of measured value

                        Pressure Dependence.

                        + 1.58 % reading per kPa deviation from normal pressure, 100 kPa

                        Annual Zero Drift7

                        < +0.3 % of measurement range

                        Measurement ranges.

                        Different sensor models from 0 - 3 000 ppm (standard) to 0 - 10 %vol.

                        Temperature Measurement


                        Operating Principle.

                        Thermistor

                        Measurement Range

                        -20 to +60 oC

                        Accuracy / Digital Resolution

                        + 0.5 oC / 0.1 oC (0.01 oC via UART)

                        Enter Buying Requirement Details
                        Email Id
                        Mobile number