                                                          Blackbody Calibration Source

                                                          Blackbody Calibration Source

                                                          Product Details:

                                                          • Material Metal
                                                          • Color Red and Black
                                                          • Voltage 220 Volt (v)
                                                          • Accuracy + 0.3 %
                                                          • Storage Temperature 500-1500 Celsius (oC)
                                                          • Operating Temperature 0-500 Celsius (oC)
                                                          • Click to View more
                                                          X

                                                          Blackbody Calibration Source Price And Quantity

                                                          • 1 Piece
                                                          • INR

                                                          Blackbody Calibration Source Product Specifications

                                                          • 220 Volt (v)
                                                          • 500-1500 Celsius (oC)
                                                          • 0-500 Celsius (oC)
                                                          • Red and Black
                                                          • Metal
                                                          • + 0.3 %

                                                          Blackbody Calibration Source Trade Information

                                                          • Cash Advance (CA) Cash in Advance (CID)
                                                          • 100 Piece Per Week
                                                          • 3 Days
                                                          • Yes
                                                          • Sample costs shipping and taxes has to be paid by the buyer
                                                          • All India

                                                          Product Description

                                                          Our competency lies in offering our clients an excellent quality assortment of Blackbody Calibration Source. It features a high emissivity of +0.99, fast heat up time and offers a 1 (25mm) aperture. Delivering a temperature range from 500C to 1500C, simply adjust the set point on the precision digital PID controller to any temperature within the specified temperature range. We provide this Blackbody Calibration Source in a number of specifications for our clients to choose from.

                                                          Specification :

                                                          Model

                                                          BBS 1500

                                                          Temperature range

                                                          500o to 1500oC

                                                          Accuracy*

                                                          + 0.3% of reading +1oC

                                                          Temperature Resolution

                                                          1 degree

                                                          Stability

                                                          < 1oC

                                                          Aperture Diameter

                                                          25mm (1.0")

                                                          Emissivity (effective)

                                                          +0.99

                                                          Cavity

                                                          Silicon Carbide

                                                          Sensor

                                                          Precision platinum thermocouple

                                                          Method of Control

                                                          Digital self-tuning PID controller

                                                          Warm-up Time

                                                          30 minutes from ambient to 1200oC

                                                          Operating Ambient Temperature

                                                          0o to 50oC

                                                          Cooling

                                                          Fan cooled

                                                          Power Requirements

                                                          220VAC, 50/60Hz, 3.8 KW (21 amps)

                                                          Dimensions (WxHxD)

                                                          22" H x 17" W x 19.5" D

                                                          Weight

                                                          60kg (132 lbs.)

                                                          Optional

                                                          115 VAC
                                                          Serial Communication: RS232 or RS485