Back to top
08045478718
Change Language
Send SMS Send Inquiry
                                                          Insertion Flowmeter for Compressed Air and Gases

                                                          Insertion Flowmeter for Compressed Air and Gases

                                                          Product Details:

                                                          • Voltage 18 - 30 Volt (v)
                                                          • Pressure 16 Bar
                                                          • Accuracy + 0.7 and 1.5 %
                                                          • Usage For Compressed Air and Gases
                                                          • Product Type Insertion Flowmeter
                                                          • Material SS
                                                          • Color White, Black and Silver
                                                          • Click to View more
                                                          X

                                                          Insertion Flowmeter for Compressed Air and Gases Price And Quantity

                                                          • 1 Piece
                                                          • INR

                                                          Insertion Flowmeter for Compressed Air and Gases Product Specifications

                                                          • + 0.7 and 1.5 %
                                                          • 16 Bar
                                                          • For Compressed Air and Gases
                                                          • 18 - 30 Volt (v)
                                                          • White, Black and Silver
                                                          • Insertion Flowmeter
                                                          • SS

                                                          Insertion Flowmeter for Compressed Air and Gases Trade Information

                                                          • Cash in Advance (CID) Cash Advance (CA)
                                                          • 100 Piece Per Week
                                                          • 3 Days
                                                          • Yes
                                                          • Sample costs shipping and taxes has to be paid by the buyer
                                                          • All India

                                                          Product Description

                                                          Our enterprise is an outstanding exporter and importer of a huge array of Insertion Flowmeter for Compressed Air and Gases. The flowmeter given by us is ideally used for the volumetric measurements of gases and liquids.  This meter is examined against diverse quality norms under the strict vigilance of experienced experts to ensure flawless supplies. For ensuring zero defects in products, insertion flowmeter for compressed air and gases undergo various quality evaluation stages conducted by our professionals on the set industry norms and standards.

                                                          Technical Data :

                                                          Measuring value


                                                          Flow


                                                          Measurand

                                                          Volumetric flow at standard conditions acc. DIN 1343 P0 = 1013.25 mbar (14.7 PSI); t0 = 0 oC (32 oF)

                                                          Measuring range

                                                          0.2...100 Nm/s (40...19685 SFPM) or 0.2...200 Nm/s (40...39370 SFPM)

                                                          Accuracy in air at 9bar (130.5psi) (abs) and 23oC (73oF)1)

                                                          + (1.5% of measuring value + 0.8% of full scale)

                                                          Temperature coefficient

                                                          + (0.1% of measuring value / oC)

                                                          Pressure coefficient 2)

                                                          + 0.5% of measuring value / bar

                                                          Response time t90

                                                          < 1 sec.

                                                          Sample rate

                                                          0.5 sec.

                                                          Temperature


                                                          Measuring range

                                                          -20...80 oC (-4...176 oF)

                                                          Accuracy at 20oC (68oF)

                                                          + 0.7 oC (1.26 °F)

                                                          Outputs


                                                          Output signal and display ranges are freely scalable Analogue output
                                                          voltage
                                                          current (3-wire)



                                                          0 - 10 V max. 1 mA
                                                          0 - 20 mA and 4 - 20 mA RL<500 Ohm

                                                          Switching output

                                                          potential-free max. 44 VDC, 500 mA switching capacity

                                                          Pulse output

                                                          Totalizer, pulse length: 0.02...2 sec.

                                                          Bus interface

                                                          MODBUS RTU or M-BUS (Meter-Bus)

                                                          Digital interface

                                                          USB (for configuration)

                                                          Input

                                                          Optional pressure compensation

                                                          4 - 20 mA (2-wire; 15 V) for pressure sensor

                                                          General

                                                          Supply voltage

                                                          18 - 30 V AC/DC

                                                          Current consumption

                                                          max. 200 mA

                                                          Temperature range

                                                          ambient temperature: -20...60 oC (-4...140 oF)
                                                          medium temperature: -20...80 oC (-4...176 oF)
                                                          storage temperature: -20...60 oC (-4...140 oF)

                                                          Humidity working range

                                                          0...99 %RH no condensation

                                                          max. working pressure

                                                          16 bar (232 Psi)

                                                          Medium

                                                          compressed air or Non-Corrosive gases

                                                          Electrical connection

                                                          cable gland M16x1.5 (optional connector M12x1 8pol.)

                                                          Electromagnetic compatibility

                                                          EN61326-1 EN61326-2-3 Industrial Environment

                                                          Material :
                                                          housing
                                                          probe
                                                          sensor head
                                                          non-return protection


                                                          metal (AlSi3Cu)
                                                          stainless steel
                                                          stainless steel / glass
                                                          brass

                                                          Housing protection class

                                                          IP65 / Nema 4

                                                          Enter Buying Requirement Details